Subjects
- Resolve problems in hydronic systems
- Safely handle refrigerants and lubricants
- Select refrigerant piping, accessories and associated controls
- Prepare to work safely in the construction industry
- Resolve problems in industrial refrigeration systems
- Implement and monitor energy sector environmental and sustainable policies and procedures
- Repair and service ammonia refrigeration systems
- Disconnect - reconnect electrical equipment connected to low voltage (LV) installation wiring
- Monitor and adjust refrigeration energy management systems
- Repair and service carbon dioxide refrigeration systems
- Install, commission, service and maintain medium temperature systems
- Commission complex refrigeration/air conditioning control systems
- Find and rectify faults in single phase motors and associated controls
- Resolve problems in central plant air conditioning systems
- Commission complex heating, ventilation and air conditioning (HVAC) systems
- Use drawings, diagrams, schedules, standards, codes and specifications
- Operate application software packages
- Repair and service self-contained carbon dioxide refrigeration and heat pump systems
- Maintain microbial control of refrigeration and air conditioning systems
- Install, commission, service and maintain low temperature systems
- Resolve problems in post-mix refrigeration systems
- Maintain documentation
- Inspect, test and repair fire and smoke control features of mechanical services systems
- Implement and monitor energy sector WHS policies and procedures
- Resolve problems in refrigerated beverage vending cabinets
- Source and purchase material/parts for installation or service jobs
- Solve problems in ELV single path circuits
- Fabricate, assemble and dismantle utilities industry components
- Install, commission, service and maintain air conditioning systems
- Fix and secure electrotechnology equipment
- Install and commission ammonia refrigeration systems, components and associated equipment
- Comply with scheduled and preventative maintenance program processes
- Install refrigerant pipe work, flow controls and accessories
- Participate in development and follow a personal competency development plan
- Resolve problems in beverage dispensers
- Repair and service secondary refrigeration systems
- Recover and charge refrigerants
- Apply safety awareness and legal requirements for carbon dioxide refrigerant
- Install and commission carbon dioxide refrigeration systems, components and associated equipment
- Develop and implement energy sector maintenance programs
- Provide basic instruction in the use of electrotechnology apparatus
- Establish the basic operating conditions of vapour compression systems
- Resolve problems in transport refrigeration systems
- Deliver a service to customers
- Diagnose and rectify faults in air conditioning and refrigeration control systems
- Document and apply measures to control WHS risks associated with electrotechnology work
- Service and repair self-contained flammable refrigerants air conditioning and refrigeration systems
- Attach cords, cables and plugs to electrical equipment for connection to 1000 V a.c. or 1500 V d.c.
- Apply work health and safety regulations, codes and practices in the workplace
- Commission refrigeration/air conditioning hydronic systems
- Diagnose faults in complex HVAC/refrigeration control systems
- Find and rectify faults in three phase motors and associated controls
- Provide cardiopulmonary resuscitation
- Resolve problems in ice making systems
- Develop, enter and verify discrete control programs for programmable controllers
- Provide quotations for installation or service jobs
- Install and commission flammable refrigerant air conditioning and refrigeration systems
- Diagnose and rectify faults in complex air conditioning/refrigeration systems
- Verify functionality and compliance of refrigeration and air conditioning installations
- Commission complex refrigeration systems and equipment
- Assemble, enter and verify operating instructions in microprocessor equipped devices
- Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply
- Establish the basic operating conditions of air conditioning systems
- Locate and rectify faults in low voltage (LV) electrical equipment using set procedures
- Prepare and connect refrigerant tubing and fittings
- Develop, enter and verify word and analogue control programs for programmable logic controllers
- Develop, enter and verify programs in supervisory control and data acquisition systems
- Resolve problems in ultra-low temperature refrigeration systems
- Establish legal and risk management requirements of new business ventures
- Compile and produce an energy sector detailed report
- Apply safety awareness and legal requirements for ammonia refrigerant
- Install, commission, service and maintain variable refrigerant flow air conditioning systems
- Apply safety awareness and legal requirements for flammable refrigerants